Security Centres 808 Manual de usuario

Busca en linea o descarga Manual de usuario para Los Sistemas De Control De Acceso De Seguridad Security Centres 808. Security Centres 808 User's Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 22
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
496336 Issue 1 1 of 22
808
Installation and User Guide
Compatible Equipment
927 8 character LCD keypad new style case
929 8 character LCD keypad
947 Portable printer ( Battery powered ) and power supply unit
949 Wall Mounted Printer Bracket
951 Printer lead
9040 16 Ohm internal sounder
9056 Plug-on Digital Communicator
Plug-on RedCare STU (manufactured by others)
9076-01/2 Signalling Interfaces
Vista de pagina 0
1 2 3 4 5 6 ... 21 22

Indice de contenidos

Pagina 1 - Installation and User Guide

496336 Issue 1 1 of 22808Installation and User GuideCompatible Equipment927 8 character LCD keypad new style case929 8 character LCD keypad947 Portab

Pagina 2 - Introduction

10 of 22 496336 Issue 1Programming Chart 808Allocate Areas to LevelsAllocate keyzones to LevelsAllocate Exit ModeSet Exit TimeSet Entry TimeSelect Ala

Pagina 3 - Technical Specification

496336 Issue 1 11 of 22808 Programming ChartInstaller CodeAudible/Silent/HiddenTamper, audible, or silentZone omission24hr omissionInstaller resetAnti

Pagina 4 - Software Limits

12 of 22 496336 Issue 1Changing Menu ItemsAfter selecting a menu, press Enter to see further options belonging to thatmenu. The system usually display

Pagina 5 - 496336 Issue 1 5 of 22

496336 Issue 1 13 of 22The display shows the zone number and current attribute.Note that the zone number is flashing (shown here by anunderline). Z01-

Pagina 6 - Wiring 927 Keypads

14 of 22 496336 Issue 112. Continue using the right and left arrow keys (C or D) to select attributesand the up or down arrow keys (A or B) to enable

Pagina 7 - Wiring FSL zones

496336 Issue 1 15 of 22Figure 5 shows which letters belong to each number key. Select the letteryou want, press the key shown the correct number of ti

Pagina 8 - Programming

16 of 22 496336 Issue 12. Press Menu.If the end station lid is open, the displays shows: REPLACE LID3. Close the end station lid.If no faults are pres

Pagina 9 - Finding Menu Items

496336 Issue 1 17 of 22Resetting Customer and Installer Codes (First stage reset)If the installer and/or user codes have been lost, or you need to ret

Pagina 10 - 10 of 22 496336 Issue 1

18 of 22 496336 Issue 18. Press Enter.The display shows: LOADING DEFAULTSFollowed by: 00:PROG SYSTEMThe end station now has the full set of Scantronic

Pagina 11 - 496336 Issue 1 11 of 22

496336 Issue 1 19 of 22Menu 50: Program outputsMenu 51: Output Types = Bell = Normally On, Strobe = NormallyOff, All other NO FunctionMenu 52: Inter

Pagina 12 - Zone Programming

2 of 22 496336 Issue 1IntroductionThe 808 is a programmable Alarm System suitable for domestic or smallcommercial premises.The system comprises an end

Pagina 13 - 496336 Issue 1 13 of 22

20 of 22 496336 Issue 1you have removed power from the end station while in programming modewith a configuration error.)The end station will not let y

Pagina 14 - Entering Text

496336 Issue 1 21 of 22The Supervisor can give users 02 to 08 one or more of the following accessrights:• Enter a Duress code.• Either Full use (set a

Pagina 15 - Leaving Programming Mode

22 of 22 496336 Issue 1To gain access to these menus from a keypad the user must key in:[Access Code] + [Menu key] + [Menu Number]For more information

Pagina 16 - Engineer Reset

496336 Issue 1 3 of 22Technical SpecificationGeneralOperating temperature = -10º - +40ºC.Humidity = 80% RH.Dimensions (end station) = h x w x d 300 x

Pagina 17 - 496336 Issue 1 17 of 22

4 of 22 496336 Issue 1Zone WiringThe recommended maximum distance for FSL zones using standard alarmcable is 200m - 300m.Software LimitsThe 808 can su

Pagina 18 - Factory Defaults

496336 Issue 1 5 of 22Enabling/Disabling Keys, Display and Sounder5. Press ‘Enter’.LED 2 lights and the display shows the status of the keypad sounder

Pagina 19 - Fault Finding

6 of 22 496336 Issue 1WiringThe 808 main PCB has facilities for connecting:Four keypads.Eight 2-wire FSL detector zones or eight 4-wire closed circuit

Pagina 20 - User Facilities

496336 Issue 1 7 of 22I/PSNDSIGSRQ+VE0VProgTest12VolDisplayRear of keypad pcbTamperN/O ExitTerminateButton orN/C Lock SetSwitchEnd StationConnections0

Pagina 21 - Operating the System

8 of 22 496336 Issue 12k2 EOL4k7Zone 1CCTAlarm contactsTamper LoopZone 1ATNote: When wiring FSL zones, link out theanti-tamper terminals of each zone

Pagina 22 - Installer Setting

496336 Issue 1 9 of 224. Press 0.The display shows: 0:INST PROG5. Press Enter.The display prompts you to remove the end station lid: REMOVE LID6. If t

Comentarios a estos manuales

Sin comentarios